use the up button to return to the Troubleshooting indexSAFETY SYSTEMThe safety system is designed to help prevent damage to the crane that would be caused by overload or two-blocking. The system consists of a load sensor, anti-two block device (optional on smaller, electric cranes), and limiting system control board. When the applicable switch detects an overload or two-block condition, the limiting system will prevent activation of winch up, boom down, and extend out since these directions would cause damage. Winch down, boom up, extend in, and power rotation will still function so that the crane can be moved to a safe configuration. CAUTION! Never de-activate or override safety functions. Doing so can result in serious damage to the crane and possibly injury or death. LOAD SENSORA pressure activated switch in the elevation cylinder acts as a load sensor. This switch is normally closed and opens at the preset pressure corresponding to the load rating of the crane. CAUTION! The load sensor will not function when the elevation cylinder is fully retracted and is inaccurate when the boom is below horizontal. CAUTION! The operator must never rely strictly on the load sensor to determine overload conditions. The load and load limits must always be known and adhered to. ANTI-TWO BLOCKThe anti-two block device (optional on smaller electric cranes), mounted on the boom crown plate, consists of a normally open switch actuated by a lever. A weight is attached to the lever and holds the switch closed. If the weight is lifted by the hook or travel block the switch opens. The power and signal wires are wired through the cord reel, which is in turn wired to the ATB switch. LIMITING SYSTEM CONTROLThe limiting system control prevents output of winch up, boom down and extend out if it is not receiving a signal from either the ATB or load sensor. The ATB does not trip boom down when winch is mounted on the boom. There is a one second delay before deactivation of boom down when the load sensor is tripped to prevent false readings caused by pressure spikes. MISCELLANEOUSUP LIMIT SWITCHThe up limit switch prevents the elevation cylinder from reaching full extension. If the elevation cylinder were to “dead-head”, the resulting pressure would activate the load sensor, preventing boom down. The boom would then have to be lowered using the manual operation buttons on the solenoid valves. CIRCUIT BREAKER, FUSEFor electric cranes a 150 Amp circuit breaker is supplied with the crane. It should be installed as close to the battery as possible. For hydraulic cranes a 10 Amp blade type fuse is supplied. DISCONNECT SWITCHA power disconnect switch is supplied with the crane. Power to the crane should be turned off whenever not in use. This is to prevent inadvertent or unauthorized use and will help prevent corrosion at electrical connections. |
|
© Copyright 2010 Liftmoore Inc., All Rights Reserved
Comments or questions about this web site
contact
bcardwell@liftmoore.com
|